Checked Wire
Fractures in a wire surface that resemble “checks” or “crow’s feet.” Checked wire is most commonly found in rod rolled from wire bar. It is usually traced to impurities on or near the rod surface, and often such defects are related to an inhomogeneous deformation in the surface region. This occurs when the drawing process uses too big an approach angle in combination with a low reduction value.